Power Failure Transfer - Panasonic KX-TD1232E Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD1232E:
Table of Contents

Advertisement

3
Features
Programming References
Feature References
Operation References
P
ower Failure Transfer
Description
Conditions
Connection References
Programming References
Feature References
Operation References
• In the event of a power failure, system memory is protected by the
factory-provided lithium battery. There is no memory loss except the
memories of Camp-On and Call Park. However if the system finds the
wrong system data, the indication "Memory data loss" is displayed on
the display proprietary telephone of Operator 1.
No programming required.
None
Not applicable.
If a power failure should happen, or during a system-off-line state,
single line telephone (SLT) which is connected the Power Failure
jack should be connected straight to specific CO lines.
Connections between the CO lines and the SLTs are as follows:
KX-TD816
The power failure transfer jacks – CO 1, 2, 5
KX-TD1232
The power failure transfer jacks of Master System – CO 1, 2, 9
The power failure transfer jacks of Slave System – CO 13, 14, 21
• Only SLT is available during a power failure.
• If the power is restored during a call using a SLT, the call is
disconnected.
Section 2, Installation,
2.3.2 Extension Connection
2.4.2 CO Line Connection (Optional Card)
2.5
Auxiliary Connection for Power Failure Transfer
No programming required.
Section 3, Features,
Power Failure Restart
Not applicable.
P
Features
3-139

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-td816e

Table of Contents