PCIe NIC cards
Description
InfiniBand EDR/EN 100-GB 1-port 840QSFP28
1 2
Adapter
InfiniBand EDR/EN 100-GB 2-port 840QSFP28
1 2
Adapter
100-GB 1-port OP101 QSFP28 x8 Intel Omni-path
1 2
architecture Adapter
Ethernet 10/25GB 2-port 640SFP28 Adapter
Ethernet 10/25GB 2-port 640FLR-SFP28 Adapter
1
If a low-profile or single-width PCIe card is installed in slot 2 of the FlexibleLOM 2U node riser cage
assembly (PN 798184-B21), and the Intel
XL190r Gen9 Server Node, the maximum inlet ambient temperature is 20°C (68°F).
2
The maximum inlet ambient temperature varies depending on the node (1U or 2U) and the type of cable
(optical fiber cable or copper direct-attach cable).
Maximum inlet ambient temperature
20°C (68°F) if using an optical fiber cable in a 2U
node
21°C (69.8°F) if using an optical fiber cable in a 1U
node
22°C (71.6°F) if using a copper direct-attach cable in
a 2U node
23°C (73.4°F) if using a copper cable in a 1U node
20°C (68°F) if using an optical fiber cable in a 2U
node
21°C (69.8°F) if using an optical fiber cable in a 1U
node
22°C (71.6°F) if using a copper direct-attach cable in
a 2U node
23°C (73.4°F) if using a copper direct-attach cable in
a 1U node
21°C (69.8°F) in a 2U node
24°C (75.2°F) in a 1U node
1 2
16°C (60.8°F) if using an optical fiber cable in a 2U
node
20°C (68°F) if using an optical fiber cable in a 1U
node
24°C (75.2°F) if using a copper direct-attach cable in
a 2U node
24°C (75.2°F) if using a copper direct-attach cable in
a 1U node
1 2
20°C (68°F) if using an optical fiber cable in a 1U
node
24°C (75.2°F) if using a copper direct-attach cable in
a 1U node
®
®
Xeon
Processor E5-2643 v4 is installed in the HPE ProLiant
Specifications