-10.7
Program the BW500 as follows:
Parameter
P390 = 1
P391-01 = 6.94
P391-02 = 13.89
P391-03 = 20.83
P391-04 = 27.78
P391-05 = 34.72
P392-01 = - 10.7
P392-02 = 11. 1
P392-03 = - 5.1
P392-04 = 8.7
P392-05 = -6.0
Often only one point of compensation is required, usually at a low load
Note:
value. In the prior example, if compensation was only required at 6.94 kg/m, the
programming could be as follows. Compensation is optimized by establishing the
next load value that agrees with the material test, hence where compensation is
zero and entering it as the next compensation point.
P390 = 1
P391-01 = 6.94
P391-02 = 20.00
P392-01 = -10.7
P392-02 = 0
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
= - 10.7
-6.0
8.7
-5.1
11.1
Load - kg/m
actual weight per material test
totalized weight by BW500
belt scale response
linearized BW500 response
internal response 100% - 150% of span
% compensation
span (100%)
Function
linearization – on
point 1, load
point 2, load
point 3, load
point 4, load
point 5, load
point 1, compensation
point 2, compensation
point 3, compensation
point 4, compensation
point 5, compensation
linearization on
point 1, load
point 2, load
point 1, compensation
point 2, compensation