Siemens Milltronics BW500 Operating Lnstructions page 120

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

P016
Belt Length
The length of the conveyor belt (one belt revolution) (
Length units are:
feet:
if the imperial system of measurement has been selected, P004 = 1
metres:
if the metric system of measurement has been selected, P004 = 2
Enter the belt length.
P017
Test Load
The load to be referenced when performing a span (
Load units are:
lb/ft: if the imperial system of measurement has been selected, P004 = 1
kg/m: if the metric system of measurement has been selected, P004 = 2
The display indicates the test reference as selected by P002: 'weight' , 'chain' , or 'ECal' and
the multispan number MS, 1-8
Enter the test load value.
In the case of weight, pressing enter at P017 invokes P680 for data entry.
In the case of ECal, pressing enter at P017 invokes P693 for data entry. ECal sets the value
for P017 at 100% of design load (P952).
In the case of chain, pressing enter at P017 allows direct entry of the load value stamped
on the chain's name plate.
If P002 is set to 'weight' the test load parameter presents two options:
1) enter the load in weight/unit length
P680 Test Load: Weight (Options)
Set
enter the desired value for P017
or
2) the mass and the weigh length.
P680 Test Load: Weight (Options)
Set
enter the 'Total Mass of Test Weights' in P681, and the ' A verage Idler Space' in
P682.
Example:
3 standard MSI test weights, 1.2 meter idler spacing
Test Load = 24.6 kg (3x8.2 kg) = 20.5 kg/m
1)
Multispan function is not available with BW500/L.
Page 114
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
1)
.
1.2 m
f
= 0.000)
f
= 0.00).
on page 139 to '1-Enter Value' , and then
on page 139 to '2-Enter Data' and then
7ML19985DK05