Siemens Milltronics BW500 Operating Lnstructions page 42

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

Press
Load Cell Balancing A & B
Place weight at cell A and press ENTER
Press
Load Cell Balancing A & B
Load cells are now balanced.
if four load cell scale, press
P295 Load Cell Balancing:
Select: 1-A&B, 2-C&D
Press
P295 Load Cell Balancing:
Select: 1-A&B, 2-C&D
Press
Load Cell Balancing C & D
Place weight at cell D and press ENTER.
Page 36
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
'B'
'B'
to continue
test weight
test weight
Balancing the load cells requires a subse-
quent zero and span calibration
V
1
E
1
' A '
' A '