P368
Direct Span Entry
Directly enters the span reference count for the span selected, span 1 to 8 (P368-01 to -
1)
08)
.
Direct entry is intended for use when replacing software or hardware and it is not
convenient to perform an initial span at that time (
Recalibration
Refer to
P370
Zero Limit Deviation %
Sets the zero calibration deviation limit () from the last initial zero. If the accumulated
deviation of successive zero calibrations exceeds the limit, the zero calibration is aborted
f
(
= 12.5)
.
If the legal for trade certification switch has been set, the zero limit is
Note:
±2%.
Enter the maximum allowable % deviation, range is 1 to 12.5 %.
P371
Auto Zero Initiation Upper Limit
This parameter sets maximum load on the belt as a percentage of design load at which
the device will allow 'auto-zero' to run, min. 1.0%, max. 10.0%, default 2.0%.
When the certification switch is set this parameter will assume the default value (2.0%).
material will not be totalized during auto zero calibrations.
Note:
P377
Initial Zero
Resets the initial zero.
The initial zero is the reference zero to which all subsequent operator initiated zero
calibrations are compared in determining whether they have deviated beyond the zero
f
limit (P370) (
= 1)
Refer to
Note:
P388
Initial Span
Resets the initial span for the span selected, multispan 1 to 8 (P388-01 to -08)
1)
BW500/L has one span entry possible, no indices will be presented.
Page 128
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
on page 41 for execution.
.
Initial Zero
on page 46 for execution.
f
= 0).
1)
.
7ML19985DK05