P697
ECal Idler Spacing
Enters the measured distance between the weighing idlers. Refer to the associated belt
scale instruction manual (
Distance units are:
feet:
if the imperial system of measurement has been selected, P004 = 1
metres:
if the metric system of measurement has been selected, P004 = 2
Enter the distance to three decimal points.
P698
ECal Conveyor Inclination
Enters the inclination or declination angle of the conveyor at the point where the belt
scale is installed (
Enter the inclination in degrees.
Upon entry, display jumps to P017 to display the design load value as the test load.
P699
ECal mV Span
Enter the mV span corresponding to 0 to 100% full scale load.
Upon entry, display jumps to P017 to display the design load value as the test load.
P735
Back Light
Sets the intensity of the back light for the LCD (
Entry:
0 = off
1 to 10 = low to high
Page 142
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
f
= 1.0).
f
= 0.0000).
f
= 10).