Siemens Milltronics BW500 Operating Lnstructions page 40

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

Press
P016 Belt Length
Enter Length
Press
P017 Test Load: Weight MS 1
Enter test load
If P002 Test Load Reference had been set for 2-Chain, the display would read:
P017 Test Load: Chain MS 1
Enter test load
or, if 3-ECal refer to ECal parameters (P693 - P699 on page 141)
P017 Test Load: ECal MS 1
Enter test load
or, if P002 is set to 1-Weight, pressing enter at P017 invokes P680 for data entry.
Press
P680 Test Load: Weight MS 1
1-Enter Value, 2-Enter Data
Select: 1 - Enter Value
The program returns to P017.
Press
P017 Test Load: Weight MS 1
Enter test load
Press
e.g. test load of 20.5 kg/m
This value is calculated. For manual or automatic calculation, refer to P680 on page 139.
The test load value should be less than the design load (P952). If not, contact Siemens.
Page 34
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
E
e.g. belt length of 25 m
0.000 m
V
0.00 kg/m
V
0.00 kg/m
V
0.00 kg/m
V
0
Select: 2 - Enter Data
The program advances through parameters
P681 and P682 prompting entry of the total
mass of all the test weights used for SPAN cali-
bration and the average measured idler space
before and after the scale. From this data the
test load is calculated and automatically
entered into P017
E
P681 Step 1: Total Mass of Test
Weights
00.00
Units are selected in P004: metric, imperial.
P682 Step 2: Average Idler Space
P017 Test Load: Weight MS 1
Enter test load
V
0.00 kg
V
0.00 m
V
00.00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: