Siemens Milltronics BW500 Operating Lnstructions page 118

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

P003
Number of Load Cells
Siemens belt scales are available in models of one, two, four, or six load cell design.
Select the number of load cells corresponding to the belt scale connected.
If using the optional remote LVDT conditioner card, for LVDT based scales, select the "1"
value.
Entry:
enter the number of load cells:
P004
Rate Measurement System
Selects system of measurement used, either imperial or metric.
Entry:
1 = imperial
f
2 = metric
P005
Design Rate Units
Determines the units for programming and measurement.
entry:
Changing this parameter does not affect the rate (P011), belt speed (P014), or belt length
(P016) parameters. These parameters should be re-entered for conformity in units.
t =1000 kg
LT=2240 lb.
T=2000 lb.
1)
For 6 load cell belt scales, enter 4
Page 112
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
BW500: 1, 2
BW500/L: 1, 2
imperial - P004 = 1
f =
T/h (tons/hour)
1
2 =
LT/h (long tons/hour)
3 =
lb/h (pounds/hour)
4 =
lb/min (pounds/minute)
f
1)
, 4, or 6
f
metric - P004 = 2
t/h (tonnes/hour)
kg/h (kilograms/hour)
kg/min (kilograms/minute)
7ML19985DK05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Milltronics bw500/l

Table of Contents