Siemens Milltronics BW500 Operating Lnstructions page 152

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

P931
Running Totalizer
1 = Total 1
2 = Total 2
3 = Verification Total
4 = Material Test Load
5 = Batch Total
6 = NTEP Total
7 = 0Cal Start Total
8 = 0Cal End Total
P940
Load Cell mV Signal Test
Displays the raw (unbalanced) mV signal input for the selected load cell, load cells A to
1)
D
(P940 – 01 to – 04)
Range 0.00 - 60.00 mV.
P943
Load Cell A/D Reference
Displays the A/D reference value for the selected load cells. These values are affected by
load cell balancing (P295).
Load cells are:
– 01 = A and B
2)
– 02 = C and D
– 03 = A and B plus C and D
– 04 = A
– 05 = B
2)
– 06 = C
2)
– 07 = D
P948
Error Log
Displays a log of the last 25 error or alarm events (P948 – 01 to – 25) that have occurred.
Event 01 is the current error.
Display:
0 = no error
# = error code; refer to
P950
Zero Register
Registers the number of zero calibrations that have been done since the last master reset
f
(
= 0).
1)
Depending on the number of load cells selected by P003, not all load cells may
be in use.
2)
Not available for BW500/L
Page 146
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
2)
Troubleshooting
on page 148
7ML19985DK05