Please read the following safety information carefully before installing the access point:
WARNING: Installation and removal of the unit must be carried out by qualified personnel only.
•  The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
•  Do not connect the unit to an A.C. outlet (power supply) without an earth (ground) connection.
•  The appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an EN 
60320/IEC 320 appliance inlet.
•  The socket outlet must be near to the unit and easily accessible. You can only remove power from the unit by disconnecting 
the power cord from the outlet.
•  This unit operates under SELV (Safety Extra Low Voltage) conditions according to IEC 60950. The conditions are only 
maintained if the equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
isolation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).
 Impédance à la terre
Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against 
the following:
U.S.A. and Canada
Denmark
Switzerland
U.K.
Europe
ii
Safety Compliance
Power Cord Safety
 supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an 
Power Cord Set
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A.
The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V) or
NEMA 6-15P (15 A, 250 V) configuration.
The supply plug must comply with Section 107-2-D1, Standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which
complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (mini-
mum).
The supply plug must comply with CEE7/7 ("SCHUKO").
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (mini-
mum).
IEC-320 receptacle.