[SwitchB-Fc1/0/3] quit
# Enable FCoE for VLAN 10, and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit
Verifying the configuration
# Display the nodes on downlink interfaces and their mapped uplink interfaces.
[SwitchA] display npv login
Server
Interface VSAN FCID
Fc1/0/1
Fc1/0/2
# Display information about uplink and downlink interfaces on Switch A.
[SwitchA] display npv status
External Interfaces:
Interface: Fc1/0/3
VSAN
1
Number of External Interfaces: 1
Server Interfaces:
Interface : Fc1/0/1
VSAN
1
Interface : fc1/0/2
VSAN
1
Number of Server Interfaces: 2
# Display the traffic mapping information on the NPV switch Switch A.
[SwitchA] display npv traffic-map
NPV traffic map information of VSAN 1:
Server Interface
Fc1/0/1
Fc1/0/2
NPV configuration example by using VFC interfaces
Network requirements
As shown in
Node WWN
1
0x010001 20:00:00:00:c8:00:e4:30 21:00:00:00:c8:60:e4:9a Fc1/0/3
1
0x010002 20:00:00:00:c9:00:e4:30 21:00:00:00:c9:60:e4:9a Fc1/0/3
VSAN tagging mode: Non Tagging
State
FCID
Up
0x010000
VSAN tagging mode: Non Tagging
State
Up
VSAN tagging mode: Non Tagging
State
Up
External Interface
Fc1/0/3
Fc1/0/3
Figure
38, configure the edge switch (Switch A) as an NPV switch to expand the network.
Port WWN
127
External
Interface