Inputs And Outputs; Input Channels - Bosch DDU 8 Manual

Table of Contents

Advertisement

5 | Inputs and Outputs

10 / 160
5
Inputs and Outputs
5.1

Input channels

Analog inputs
The DDU 8 analog inputs accept an input signal of 0 to 5 V. A 3.01 kOhm pull‐up
resistor can be activated by software.
Digital inputs
The digital inputs of the DDU 8 accept 0 V to 5 V signals of Hall‐effect sensors by
default. Connect the output of the Hall‐effect sensor to the REVn_P pin and leave
the REVn_M pin open.
Page selection switch
Pin 36 of the DDU 8 life connector is used as a page selection switch for the dis‐
play. The internal pull‐up resistor is automatically activated. Display pages are se‐
lected by connecting the pin to SENSGND with different resistor values over a 12
position switch:
Page
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
DDU 8 Manual
Resistor Value
43.9 Ohm
142 Ohm
264 Ohm
409 Ohm
609 Ohm
846 Ohm
1,180 Ohm
1,650 Ohm
2,430 Ohm
Bosch Motorsport