Honda TRX400EX FOURTRAX 1999 Service Manual page 232

Table of Contents

Advertisement

IGNITION SYSTEM
TROUBLESHOOTING
Faulty spark plug
-
Loose spark plug cap or spark plug wire connections
-
-Water got into the spark plug cap (Leaking the ignition coil secondary voltage)
If there is no spark at cylinder, temporarily exchange the ignition coil with a good one and perform the spark test. If there is
spark, the exchanged ignition coil is faulty.
No spark at spark plug
UNUSUAL CONDITION
gnition coil
Low peak voltage
No peak voltage
Peak voltage is normal, but no
spark jumps at plug
ixciter coil
Low peak voltage
No peak voltage
Low peak voltage
16-2
PROBABLE CAUSE (Check in numerical order)
1.
Incorrect peak voltage adaptor connections. (System is normal if mea-
sured voltage is over the specifications with reverse connections.)
2. The multimeter impedance is too low; 10 MOIDCV.
3. Cranking speed is too low.
4. The sampling timing of the tester and measured pulse were not
synchronized. (System is normal if measured voltage is over the
standard voltage at least once.)
5.
Poorly connected connectors or an open circuit in ignition system.
6. Faulty exciter coil. (Measure peak voltage.)
7. Faulty ignition coil.
8. Faulty ignition control module (ICM) (when above No.
are normal.)
1 . Incorrect peak voltage adaptor connections. (System
sured voltage is over the specifications with reverse connections.)
2. Short circuit in engine stop switch (blacklwhite) wire.
3.
Faulty ignition switch or engine stop switch.
4. Loose or poorly connected ICM connectors.
5.
Open circuit or poor connection in ground (greenlwhite) wire of
the ICM.
6. Faulty peakvoltage adaptor.
7. faulty exciter coil. (Measure peak voltage.)
8. Faulty ignition pulse generator. (Measure peak voltage.)
9. Faulty ICM (when above
1.
Faulty spark plug or leaking ignition coil secondary current ampere.
2.
Faultv ianition coil.
1. The multimeter impedance is too low; 10 MOIDCV.
2. Cranking speed is too slow.
Battery is undercharged.
3. The sampling timing of the tester and measured pulse were not
synchronized. (System is normal if measured voltage is over the
standard voltage at least once.)
4. Faulty exciter coil (when above
1. Faulty peak voltage adaptor.
2. Faulty exciter coil.
1. The multimeter impedance is too low; 10 MOIDCV.
2. Cranking speed is too slow.
Battery is undercharged.
3. The sampling timing of the tester and measured pulse were not
synchronized. (System is normal if measured voltage is overthe
standard voltage at least once.)
4. Faulty ignition pulse generator (when above
normal).
1.
Faulty peak voltage adaptor.
2.
Faulty ignition pulse generator.
is normal if mea-
No. 1 through
8 are normal.)
No.
1 through
3 are normal).
No.
1 through
through 7
1
3
are

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trx400ex fourtrax 2000Trx400ex fourtrax 2001

Table of Contents