Monitor Mode Commands
Load Command
Verify Command
Go Command
The data stored from &H3000 to &H300F will be transferred to port 1. If a
peripheral device other than the input terminal needs to be connected for the
data transfer, follow the peripheral data transfer procedure explained at the
beginning of this section.
Purpose:
To load a data file in S format through port 1
Format:
L[(offset)]
Examples:
1. Enter:
*L
Enter:
*L100
Press the START/STOP switch.
• Loads a data file in S format through port 1 and stores the file in memory.
2. Enter:
*3100.310F
Displayed:
3100-CE 00 00 08 26 FD 08 26
3108-FD 86 55 97 17 CE 00 00
• When an offset address is specified, the loaded file is stored in memory
starting from an address whose value is the specified address plus the
offset. Data transfer will not start until the ASCII Unit START/STOP switch
is pressed.
Purpose:
To verify whether data sent through port 1 is the same as data
stored in the specified memory locations
Format:
V[(offset)]
Example:
Enter:
*V100
Press the START/STOP switch.
Displayed:
3120-12
Remarks:
The input data is compared with the data stored in the specified address
range. The base address for data comparison is the specified address plus
the offset.
If a discrepancy is found, the address at which it occurs and the data con-
tained therein are both displayed. Data will not be verified until the ASCII Unit
START/STOP switch is pressed.
If a peripheral device other than the input terminal needs to be connected for
data transfer, follow the peripheral data transfer procedure explained at the
beginning of this section.
Purpose:
To execute a program
Format:
G[(address)]
Section 5-3
75