Front Panel
Front Panel
Indicator LEDs
ASC 02
RUN
BASIC
T / R
T / R
[
]
1
2
ERR
ERR
START
/ STOP
Machine
No.
·
·
· ·
· ·
Port 1
· ·
·
·
·
· ·
· ·
Port 2
· ·
·
Name
Run
T/R for ports 1 and 2
ERR 1 (error for port 1)
ERR 2 (error for port 2)
BASIC
Indication:
Lit
Blinking
LED Display
Indicates the operating status
of the ASCII Unit.
START/STOP switch
Starts/stops BASIC pro-
gram execution.
Machine No. switch
Sets the ASCII Unit Machine
Number
RS-232C connector port 1
Connects peripheral devices. Is
generally used to input the BA-
SIC program but can be used for
other peripheral devices as well.
RS-232C connector port 2
Connects peripheral devices. Cannot
be used to input a BASIC program. Is
generally used for a printer or other
RS232-C devices.
Indication
Lit when the ASCII Unit is operating
(green)
normally. Unlit if an error occurs.
Blinks during data transmission (port
(green)
1 and port 2).
Lit if an error such as parity error
(red)
occurs, or while the ASCII Unit is
waiting for specific transmission
conditions to be satisfied.
Blinks when the battery voltage has
(red - 1
fallen below the rated level or when
only)
the battery has not been inserted
correctly.
Lit while the BASIC program is
(green)
running.
Blinks when the BASIC program
(green)
stops, or when the ASCII Unit is
waiting for input while the BASIC
program is running.
Unlit when in monitor mode.
(green)
Unlit
Section 1-1
Function
3