Omron SYSMAC C200H-ASC02 Operation Manual page 147

Ascii unit
Hide thumbs Also See for SYSMAC C200H-ASC02:
Table of Contents

Advertisement

Troubleshooting
1.
Turn OFF power to the ASCII Unit. If power
is not supplied to the Unit, apply power to
the Unit for at least 1 minute, then turn it
OFF.
2.
Remove the ASCII Unit from the PC by
pushing down the locking lever on the PC
with a screwdriver.
3.
With a Phillips screwdriver, remove the two
screws, from the ASCII Unit.
4.
With a standard screwdriver, remove the
cover of the ASCII Unit.
5.
Pull out the PC board from the housing.
6.
Disconnect the battery and connector and
replace them with new ones.
7.
Reassemble the ASCII Unit in the reverse
order of disassembly.
Notes on Handling
Replace the ASCII Unit after turning off the power to the PC.
When returning a defective Unit to OMRON, inform us of the abnormal symptom/s in as much detail as possi-
ble.
144
Battery connector
Battery Set
C200H-BAT09
Appendix F
Back of Unit
Battery holder