Monitor Mode Commands
Disassembler Command
Save Command
74
*BP
Displayed: BP=0000 0000
Example Remarks:
Clears all the breakpoints currently set.
Purpose:
To disassemble and display 20 lines of code starting from the
specified address.
Format:
I(address)
Examples:
1. Enter:
*I 3000
Displayed:
3000-CE 10 00
3003-FF 40 00
3006-86 80
3030-81 12
• Disassembles and displays 20 lines of code starting from the specified ad-
dress.
2. Enter:
*I, I
Displayed:
3032-26 02
3034-A7 00
3036-39
.
.
3080-08
• Each time I,I is subsequently entered, the next 20 lines of code will be dis-
played.
Purpose:
To transfer the specified block of data to port 1 in S format
Format:
S(start address).(end address)
Remarks:
Transfers the data stored from (start address) to (end address) in S format to
the port 1 buffer.
Example:
Step 1:
*S3000.300F
Step 2:
Press the START/STOP switch.
Example Remarks:
LDX
STX
LDAA
.
.
.
.
CMPA
BNE
STAA
RTS
.
.
INX
Section 5-3
#$1000
$4000
#$80
.
.
#$12
$3036
$00, X