6. Maintenance/Repair
6.2. Replacing batteries
Step
ATTENTION
You must replace both batteries. Both batteries must be the same model from the same
manufacturer. Mixing old and new batteries or different manufacturers is not permitted.
Use only the following 3.6V lithium thionyl chloride (Li-SOCl2) batteries (non-rechargeable),
size D. No other batteries are approved for use in XYR 6000 Wireless Transmitters.
Xeno Energy XL-205F
Eagle Picher PT-2300H
Tadiran TL-5930/s
Honeywell p/n 50026010-001 (Two 3.6V lithium thionyl chloride batteries) (1 transmitter)
Honeywell p/n 50026010-002 (Four 3.6V lithium thionyl chloride batteries) (2 transmitters)
Honeywell p/n 50026010-003 (Ten 3.6V lithium thionyl chloride batteries) (5 transmitters)
1
Loosen the M3 locking set screw on the battery end-cap (opposite end from display). See item
1 in Figure 10. Unscrew and remove the end cap.
2
Using thumb and forefinger, squeeze the battery connector at top and bottom to disengage the
locking mechanism, then pull to disconnect. See item 2 in Figure 10.
3
Loosen the two battery holder retaining screws (closest to the batteries). See item 3 in Figure
10. The screws are captive.
4
Pull the battery holder out of the transmitter.
5
Remove the old batteries from the battery holder. If needed, pry out the batteries by using a
slotted screwdriver as a lever in the holder's side slots. See item 4 in Figure 10.
6
Insert the new batteries using correct polarity shown on the battery holder.
7
Insert the battery holder into the transmitter. Reattach the screws and tighten to 0,4 – 0,6 N-M
(3.5 – 5.3 Lb-in).
Re-connect battery connector.
Honeywell recommends lubricating the end cap O-ring with a Silicone Grease such as Dow
Corning #55 or equivalent before replacing the end cap.
8
Screw the end cap back on and tighten the M3 locking screw.
9
Dispose of used battery promptly per local regulations or the battery manufacturer's
recommendations. Keep away from children. Do not disassemble and do not dispose of in fire.