Wiring Connections

With the battery still not inserted, connect the
contact loop (if used) to the unit's loop terminals
(see diagram). The contact loop must use closed
circuit devices. The loop response time is a
nominal 100mSec.
Note: If the contact loop is not to be used, no
connection is needed across its terminals.

BATTERY INSTALLATION/REPLACEMENT

Remove the transmitter's cover (if it is not
1.
already off) as described in Mounting Step 1.
2.
Observe correct polarity and insert the
battery provided into the battery holder (see
Diagram 2). Take care not to bend the
antenna.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS:
modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized
changes or modifications could void the user's authority to operate the equipment.
FCC/IC NOTICE: This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any
interference received, including interference that may cause undesired operation.
TO THE INSTALLER: Regular maintenance and inspection (at least annually) by the installer and frequent testing
by the user are vital to continuous satisfactory operation of any alarm system. The installer should assume the
responsibility of developing and offering a regular maintenance program to the user, as well as acquainting the user
with the proper operation and limitations of the alarm system and its component parts. Recommendations must be
included for a specific program of frequent testing (at least weekly) to insure the system's operation at all times.
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS
USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
For Warranty Information on this product, please see:
http://www.security.honeywell.com/hsc/resources/wa
ÊN6482V2bŠ
N6482V2 4/98 Rev. C
Note: Replace battery only with:
Panasonic CR123A, Duracell DL123A,
Sanyo CR123A, or ADEMCO 466.
To replace the cover, engage the hooks
3.
along one edge and snap shut.

SPECIFICATIONS

Dimensions: 1-9/16"W x 3-1/16"H x 1-3/16"D
(40mm x 78mm x30mm)
Battery: 3V Lithium (see Note in step 2 of
BATTERY INSTALLATION/REPLACEMENT)
BATTERY CAUTION: Risk of fire, explosion
and burns. Do not recharge, disassemble, heat
above 212 F (100 C) or incinerate. Dispose of
used batteries promptly. Keep away from
children.
The user shall not make any changes or
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2008 Honeywell International Inc.
www.honeywell.com/security