Transmitter Menu; Menu Tree; Table 7 Menu Tree - Honeywell XYR 6000 User Manual

Temperature
Hide thumbs Also See for XYR 6000:
Table of Contents

Advertisement

5.4

Transmitter menu

Menu tree

At the PV display, press Enter to access the menus. To interact with the menus use the Device Local
Configuration. See page 20.
Menu item
CAL
CH-1
CH-2
CH-3
RADIO
PRI RSSI
SEC RSSI
NWK STAT
Revision 2
8/7/07
Description
Calibration menu. May be password-protected. See Table 8 on
page 20 for password number entry.
Channel 1.
Channel 2.
Channel 3.
CAL RSTR
Restores selected channel to factory calibration.
USER CAL
Lets you calibrate selected channel's low and high points.
CAL CLR
Clear the factory and user calibration.
EXIT
Exits calibration menu and returns to PV display.
Radio menu
Primary receive signal strength. Read only. Signal strength 00 is too
weak to connect to the network.
Displayed Value
00
01
02
03
04
05
06
07
08
09
Secondary receive signal strength. Same as PRI RSSI. Read only.
Network status. Read only.
CONNECTED means the transmitter radio and a multinode have
detected each other. It does not necessarily mean security has
been enabled or that the Wireless Builder has sensed the
transmitter.
NOT CONNECTED means radio communcations with a multinode
OneWireless XYR 6000 Temperature Transmitter User's Manual

Table 7 Menu tree

Value dBm
< -86
-86 to -81
-80 to -75
-74 to -69
-68 to -63
-62 to -57
-56 to -51
-50 to -45
-44 to -11
≥ -10
5. Operation
5.4. Transmitter menu
Rx Margin dB
< 10
10 to 15
16 to 21
22 to 27
28 to 33
34 to 39
40 to 45
46 to 51
52 to 85
Saturation
17

Advertisement

Table of Contents
loading

Table of Contents