6.2
Replacing batteries
When to replace
When the transmitter displays a LO BATT message you have 2-4 weeks to replace both batteries before
they expire. When batteries are removed or expired, all transmitter data is retained in the transmitter's non-
volatile memory.
Tools required
•
#1 Phillips Screwdriver or 1/8" Slotted Screwdriver
•
Torque Screwdriver
•
1.5 mm hex key
Procedure
ATTENTION
Batteries must be replaced only by a trained service technician.
WARNINGS
•
Risk of death or serious injury by explosion. Do not open transmitter
enclosure when an explosive gas atmosphere is present.
•
The batteries used in this device may present a risk of fire or chemical
burn if mistreated. Do not recharge, disassemble, heat above 100°C
(212°F), or incinerate.
Revision 2
8/7/07
3
Figure 9 Display/sensor module removal and replacement
OneWireless XYR 6000 Temperature Transmitter User's Manual
3
2
2
6. Maintenance/Repair
6.2. Replacing batteries
1
25