GE 350 Communications Manual page 191

Feeder protection and control
Hide thumbs Also See for 350:
Table of Contents

Advertisement

CHAPTER 8: MODBUS MEMORY MAP
Modbus
Hex
Description
Address
Address
43954
F71
Analog Input Point 3 Entry
43955
F72
Analog Input Point 3 Scale Factor
43956
F73
Analog Input Point 3 Deadband
43958
F75
Analog Input Point 4 Entry
43959
F76
Analog Input Point 4 Scale Factor
43960
F77
Analog Input Point 4 Deadband
43962
F79
Analog Input Point 5 Entry
43963
F7A
Analog Input Point 5 Scale Factor
43964
F7B
Analog Input Point 5 Deadband
43966
F7D
Analog Input Point 6 Entry
43967
F7E
Analog Input Point 6 Scale Factor
43968
F7F
Analog Input Point 6 Deadband
43970
F81
Analog Input Point 7 Entry
43971
F82
Analog Input Point 7 Scale Factor
43972
F83
Analog Input Point 7 Deadband
43974
F85
Analog Input Point 8 Entry
43975
F86
Analog Input Point 8 Scale Factor
43976
F87
Analog Input Point 8 Deadband
43978
F89
Analog Input Point 9 Entry
43979
F8A
Analog Input Point 9 Scale Factor
43980
F8B
Analog Input Point 9 Deadband
43982
F8D
Analog Input Point 10 Entry
43983
F8E
Analog Input Point 10 Scale Factor
43984
F8F
Analog Input Point 10 Deadband
43986
F91
Analog Input Point 11 Entry
43987
F92
Analog Input Point 11 Scale Factor
43988
F93
Analog Input Point 11 Deadband
43990
F95
Analog Input Point 12 Entry
43991
F96
Analog Input Point 12 Scale Factor
43992
F97
Analog Input Point 12 Deadband
43994
F99
Analog Input Point 13 Entry
43995
F9A
Analog Input Point 13 Scale Factor
43996
F9B
Analog Input Point 13 Deadband
43998
F9D
Analog Input Point 14 Entry
43999
F9E
Analog Input Point 14 Scale Factor
44000
F9F
Analog Input Point 14 Deadband
44002
FA1
Analog Input Point 15 Entry
44003
FA2
Analog Input Point 15 Scale Factor
44004
FA3
Analog Input Point 15 Deadband
44006
FA5
Analog Input Point 16 Entry
44007
FA6
Analog Input Point 16 Scale Factor
44008
FA7
Analog Input Point 16 Deadband
44010
FA9
Analog Input Point 17 Entry
44011
FAA
Analog Input Point 17 Scale Factor
44012
FAB
Analog Input Point 17 Deadband
44014
FAD
Analog Input Point 18 Entry
350 FEEDER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
Min
Max
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
1
9
0
100000000
0
49
MODBUS MEMORY MAP
Step Units
Format
Factory
Code
Default
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
1
---
F85
4
1
---
F9
30000
1
---
F88
0
Size in
Words
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
1
2
1
8–37

Hide quick links:

Advertisement

Table of Contents
loading