CHAPTER 2: RS485 INTERFACE
OBJECT
OBJECT
VARIATION
NO.
NO.
2
12
1
20
0
1
2
5
6
21
0
1
2
9
10
22
0
350 FEEDER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
DESCRIPTION
Binary Output Status
Control Relay Output Block 3 (select)4
Binary Counter (Variation 0
is used to request default
variation)
32-Bit Binary Counter
16-Bit Binary Counter
32-Bit Binary Counter
without Flag
16-Bit Binary Counter
without Flag
Frozen Counter(Variation 0
is used to request
defaultvariation)
32-Bit Frozen Counter
16-Bit Frozen Counter
32-Bit Frozen Counter
without Flag
16-Bit Frozen Counter
without Flag
Counter Change Event
(Variation 0 is used to
request default variation)
REQUEST
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
00, 01 (start-stop)
(operate) 5 (direct
07, 08 (limited
op) 6 (dir. op,
quantity) 17, 28
noack)
(index)
1 (read) 7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read)7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read) 7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read) 7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read) 7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
DNP PROTOCOL SETTINGS
RESPONSE
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
echo of request
---
---
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
2–9