Chapter 12
9) Put the sample copies in order, and clean up the area around the machine.
10) Record the latest counter readings. At this time, be sure to also record the settings of the following: 'FX-UP-RL'
and 'DV-UNIT-K'.
11) Fill out the form in the Service Book, and report to the person in charge. be sure also to indicate the check on the
leakage breaker in the history of checks.
12.3.4 Points to Note About the Scheduled Servicing
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
- If you used solvent, be sure that it has dried before putting the part back into the machine.
- Unless otherwise indicated, do not use a cloth moistened with water.
- Be sure to provide scheduled servicing at specific intervals.
[1]Copyboard glass, reading glass (clean, using water or mild detergent)