Chapter 7
 
F-7-186
7.12.9.6 Removing the Upper
Tray
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Remove the 2 screws [1], and detach the upper tray
[2].
F-7-187
Reference:
Lift the front of the upper tray [1], and detach it as if
to slide it toward the front.
7-60
7.12.9.7 Removing the Toner
Cartridge Cover
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Remove the 2 screws [1]; then, detach the toner
0007-8367
bottle cover [2].
7.12.9.8 Removing the Pre-
Exposure Lamp
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Open the 2 wire saddles [1], and disconnect the 2
relay connectors [2].
F-7-188
0007-8368
F-7-189
0007-8369