Canon iR4570 Series Service Manual page 966

Hide thumbs Also See for iR4570 Series:
Table of Contents

Advertisement

Chapter 17
 
- 172.16.1.100
- 172.16.1.255
If the settings are not as indicated below, make the appropriate changes:
Command Prompt
C:
\
M i c r o s o f t W i n d o w s 2 0 0 0 [ Ve r s i o n 5 . 0 0 . 2 1 9 5 ]
( C ) C o p y r i g h t 1 9 8 5 - 1 9 9 9 M i n c r o s o f t C o r p .
C : \ i p c o n f i g
W i n d o w s 2 0 0 0 I P C o n f i g u r a t i o n
E t h e r n e t a d a p t e r L o c a l A r e a C o n n e c t i o n :
C : \
3) Check to see that the Execute/Memory lamp on the control panel is off, and turn off the main power switch
(iR4570/3570, 2870/2270 Series).
3-1) Hold down the power switch on the control panel for 3 sec or more.
3-2) Follow the instructions indicated on the control panel so that the main power switch may be turned off.
3-3) Turn off the main power switch.
4) Connect the PC to the machine using a cross cable (iR4570/3570, 2870/2270 Series).
IP address: 172.16.1.100
Subnet mask: 255.255.255.0
17-10
C o n n e c t i o n - s p e c i f i c D N S S u f f i x
I P A d d r e s s . . . . . . . . . . . . : 1 7 2 . 1 6 . 1 . 1 6 0
S u b n e t M a s k . . . . . . . . . . . : 2 5 5 . 2 5 5 . 2 5 5 . 0
D e f a u l t G a t e w a y . . . . . . . . . :
. :
F-17-9
IP sddress: 172.16.1.160
Subnet mask: 255.255.255.0
Cross cable
10Base-T: category 3 or 5
100Base-TX: category 5
F-17-10