Removing The Duplex Feed Sensor - Canon iR4570 Series Service Manual

Hide thumbs Also See for iR4570 Series:
Table of Contents

Advertisement

1) Open the right door.
F-8-393
2) Remove the reuse band [1], and disconnect the
connector [2].
3) Remove the 2 screws (M4x8; RS tightening), and
detach the right door.
F-8-394
Attaching the Right Door
1) Match the hinge [1] found at the bottom of the right
door against the lug.
2) Engage the hinge [2] found on the top of the right
door with the hook found on the side plate.
F-8-395
When tightening the 2 screws used to fix the hinge in
place, be sure to close the right door first.
8.8.23.4 Removing the Duplex
Feed Sensor
iR2270 / iR2870 / iR3570 / iR4570 / iR3530
1) Remove the 2 screws (w/ collar) [1], and detach the
transfer frame [2].
F-8-396
2) Disconnect the connector [1], and remove the
Chapter 8
0007-6976
8-143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir 3570 seriesIr 2870 seriesIr 2270 series

Table of Contents