Configuring Fibre Channel Domain Parameters
The following example shows how to display frame and other fcdomain statistics for a specified VSAN or
SAN port channel:
switch# show fcdomain statistics vsan 1
VSAN Statistics
The following example shows how to display FC ID allocation statistics including a list of assigned and free
FC IDs:
switch# show fcdomain address-allocation vsan 1
The following example shows how to display the valid address allocation cache. The cache is used by the
principal switch to reassign the FC IDs for a device (disk or host) that exited and reentered the fabric. In the
cache content, VSAN refers to the VSAN that contains the device, WWN refers to the device that owned the
FC IDs, and mask refers to a single or entire area of FC IDs.
switch# show fcdomain address-allocation cache

Default Settings for Fibre Channel Domains

The following table lists the default settings for all fcdomain parameters.
Table 8: Default fcdomain Parameters
Parameters
fcdomain feature
Configured domain ID
Configured domain
auto-reconfigure option
contiguous-allocation option
Priority
Allowed list
Fabric name
rcf-reject
Persistent FC ID
Allowed domain ID list configuration distribution
OL-27583-01
Number of Principal Switch Selections: 5
Number of times Local Switch was Principal: 0
Number of 'Build Fabric's: 3
Number of 'Fabric Reconfigurations': 0

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)

Default Settings for Fibre Channel Domains
Default
Enabled
0 (zero)
Preferred
Disabled
Disabled
128
1 to 239
20:01:00:05:30:00:28:df
Disabled
Enabled
Disabled
53