Cisco Nexus 5000 Series Nx-Os San Switching Configuration Guide, Release 5.2(1)N1(1 - Cisco Nexus 5000 Series Configuration Manual

Nx-os san
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Configuring FCoE NPV
Hardware is Virtual Fibre Channel
Port WWN is 20:00:00:05:9b:74:bd:bf
Admin port mode is F, trunk mode is on
snmp link state traps are enabled
Port mode is TF
Port vsan is 20
Trunk vsans (admin allowed and active) (1,20,100,200,300,400,500)
Trunk vsans (up)
Trunk vsans (isolated)
Trunk vsans (initializing)
1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
last clearing of "show interface" counters Tue May 31 20:56:41 2011
Interface last changed at Wed Jun
This example shows the information about the NPV FLOGI session:
switch# show npv flogi-table
--------------------------------------------------------------------------------
SERVER
INTERFACE VSAN FCID
--------------------------------------------------------------------------------
vfc1
Total number of flogi = 1.
This example shows the status of the NPV configuration including information about VNP ports:
switch# show npv status
npiv is enabled
disruptive load balancing is disabled
External Interfaces:
====================
Interface:
Interface:
Interface: vfc90,
Interface: vfc100, State: Down
Interface: vfc110, State: Down
Interface: vfc111, State: Down
Interface: vfc120, State: Down
Interface: vfc130, State: Trunking
Number of External Interfaces: 8
Server Interfaces:
OL-27583-01
355278397 frames input, 573433988904 bytes
0 discards, 0 errors
391579316 frames output, 572319570200 bytes
0 discards, 0 errors
20
0x670000 21:01:00:1b:32:2a:e5:b8 20:01:00:1b:32:2a:e5:b8 fc2/6
fc2/5, State: Trunking
VSAN:
1, State: Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
20, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10000
fc2/6, State: Trunking
VSAN:
1, State: Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
20, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10001
State: Down
VSAN:
1, State: Waiting For VSAN Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10002

Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)

(20)
()
(1,100,200,300,400,500)
1 20:25:36 2011
PORT NAME
Configuration Examples for FCoE NPV
EXTERNAL
NODE NAME
INTERFACE
83

Advertisement

Table of Contents
loading

Table of Contents