4. Thermo switch 2
• Remove the thermo switch 2 from the wire
harness.
• Connect the pocket tester (Ω × 1) to the
thermo switch 2 1.
• Immerse the thermo switch 2 in a con-
tainer filled with water 2.
• Place a thermometer 3 in the water.
• Slowly heat the water, than let it cool to the
specified temperature as indicated in the
table.
• Check the thermo switch 2 for continuity at
the temperatures indicated in the table.
È The thermo switch 2 circuit is closed.
É The thermo switch 2 circuit is open.
Test step
Water temperature Continuity
Less than 16 ± 3 °C
1
(60.8 ± 5.4 °F)
More than 16 ± 3 °C
2
(60.8 ± 5.4 °F)
More than 11 ± 3 °C
3
(51.8 ± 5.4 °F)
Less than 11 ± 3 °C
4
(51.8 ± 5.4 °F)
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
*
CARBURETOR HEATING SYSTEM
Yes
No
No
Yes
GOOD
CONDITION
9 - 59
3
1
BAD CONDITION
Replace the thermo switch 2.
+