Chapter 8 Parameters
ASH3
P4-02★
Operational
Interface:
Default: 0
Control
Mode:
Range: -
Data Size: 32-bit
Format: Hexadecimal
Settings: The last third abnormal status record
ASH4
P4-03★
Operational
Interface:
Default: 0
Control
Mode:
Range: -
Data Size: 32-bit
Format: Hexadecimal
Settings: The last fourth abnormal status record
8-148
Fault Record (N-2)
Panel / Software
ALL
Unit: -
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET
Fault Record (N-3)
Panel / Software
ALL
Unit: -
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET
Communication
Communication
ASDA-A2
Address: 0404H
0405H
Related Section:
4.4.1
Address: 0406H
0407H
Related Section:
4.4.1