This feature senses when the scanner is removed from the stand and tells it to
begin manual triggering. When Sensor On is enabled, the scanner defaults to
Streaming Presentation Mode when it is in the stand, and to Manual Trigger Mode
when it is removed from the stand. Default = Sensor On.
Note: If you are taking images (see
set the In-Stand Sensor to Off.
You may program a Streaming Presentation Mode (Normal, Enhanced, or Mobile
Phone) you wish to use for in-stand scanning, and a Manual Trigger mode (Nor-
mal, Enhanced, or Mobile Phone) you wish to use for out-of-stand scanning. To do
this, you must first scan the preferred Streaming Presentation mode (see below),
then scan the Manual Trigger mode (see
Poor Quality Codes
Poor Quality 1D Codes
This setting improves the scanner's ability to read damaged or badly printed linear
bar codes. When Poor Quality 1D Reading On is scanned, poor quality linear bar
code reading is improved, but the scanner's snappiness is decreased, making it
less aggressive when reading good quality bar codes. This setting does not affect
2D bar code reading. Default = Poor Quality 1D Reading Off.
Poor Quality 1D Reading On
Poor Quality PDF Codes
This setting improves the scanner's ability to read damaged or badly printed PDF
codes by combining information from multiple images. When Poor Quality PDF
On is scanned, poor quality PDF code reading is improved, but the scanner's snap-
Xenon/Granit User Guide
* Sensor On
Imaging Commands
page 117
Sensor Off
beginning on page 233), you must
and
page
125) you want to use.
* Poor Quality 1D Reading Off
123