Bit Switches
3-second CNG interval.
High order bit
Low order bit
G3 Switch 0F [SP No. 1-105-016]
No
FUNCTION
Alarm when an error occurred
in Phase C or later
0
0: Disabled
1: Enabled
Alarm when the handset is off-
hook at the end of
1
communication
0: Disabled
1: Enabled
2
Not used
Sidaa manual calibration
setting
4
0: Off
1: On
5-7 Not used

4.3.6 G3-2/3 SWITCHES

These switches require an optional G3 interface unit.
G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00 [SP No. 1-106-001]
No
FUNCTION
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
0-1
Bit 1: 0, Bit 0: 1 = Up to Phase
B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Not used
2
Monitor speaker during
B786
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ FF (2250
ms)
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ 0F (3700
ms)
COMMENTS
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
Do not change the settings.
1: manually calibrates for communication with a
line, whose current change occurs such as an
optical fiber line.
Do not change the settings.
COMMENTS
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that
you reset these bits after testing.
1: The monitor speaker is enabled during memory