Ricoh B230 Service Manual page 1042

Hide thumbs Also See for B230:
Table of Contents

Advertisement

Bit Switches
No
FUNCTION
Point of resumption of
memory transmission upon
0
redialing
0: From the error page
1: From page 1
1-7 Not used
Communication Switch 0B - Not used (do not change the settings)
Communication Switch 0C - Not used (do not change the settings)
Communication Switch 0D [SP No. 1-104-014]
No
FUNCTION
The available memory
threshold, below which ringing
0-7
detection (and therefore
reception into memory) is
disabled
Communication Switch 0E [SP No. 1-104-015]
No
FUNCTION
Minimum interval between
0-7
automatic dialing attempts
Communication Switch 0F – Not used (do not change the settings.)
Communication Switch 10 [SP No. 1-104-017]
No
FUNCTION
Memory transmission:
0-7
Maximum number of dialing
attempts to the same
B786
COMMENTS
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
Do not change the settings.
COMMENTS
00 to FF (Hex), unit = 4 kbytes
(e.g., 06(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each fax
reception. If the amount of remaining memory is
below this threshold, the machine cannot receive
any fax messages.
If this setting is kept at 0, the machine will detect
ringing signals and go into receive mode even if
there is no memory available. This will result in
communication failure.
COMMENTS
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine
waits before it dials the next destination.
COMMENTS
01 – FE (Hex) times
70
SM