Ricoh B230 Service Manual page 1044

Hide thumbs Also See for B230:
Table of Contents

Advertisement

Bit Switches
No
FUNCTION
0
Not used
Optional G3 unit (G3-2)
1
0: Off
1: On
2
Not used
Optional G3 unit (G3-3)
3
0: Off
1: On
4-7 Not used
Communication Switch 17 [SP No. 1-104-024]
No
FUNCTION
SEP reception
0
0: Disabled
1: Enabled
SUB reception
1
0: Disabled
1: Enabled
PWD reception
2
0: Disabled
1: Enabled
3-6 Not used
Action when there is no box
with an F-code that matches
the received SUB code
7
0: Disconnect the line
1: Receive the message
(using normal reception
mode)
Communication Switch 18 [SP No. 1-104-025]
No
FUNCTION
0-4 Not used
IP-Fax dial-in routing selection
5
0: Off
1: On
6-7 Not used
B786
COMMENTS
Do not change the factory settings.
Change this bit to "1" when installing the first
optional G3 unit (G3-2).
Do not change the factory settings.
Change this bit to "1" when installing the second
optional G3 unit (G3-3).
Do not change the factory settings.
COMMENTS
0: Polling transmission to another maker's
machine using the SEP (Selective Polling) signal
is disabled.
0: Confidential reception to another maker's
machine using the SUB (Sub-address) signal is
disabled.
0: Disables features that require PWD (Password)
signal reception.
Do not change the factory settings.
Change this setting when the customer requires.
COMMENTS
Do not change the factory settings.
1: Transfers receiving data to each IP-Fax dial-in
number.
IP-Fax dial-in number is 4 digit-number.
Do not change the factory settings.
72