06.90
8 Monitoring
8.3.3 List of alarms
6109
Overflow block stack
Nesting depth > 12
PLC-STOP
When a block
calls
itself
Correct program
Cause:
Effect:
Explanation:
Remedy:
6110
Overflow interrupt stack
More than
two
U-STACK entries
PLC-STOP
Cyclic program (OB
1)
is interrupted by alarm program
(OB 2)
and alarm
program interrupts itself
See
processing delay
OB
2,
alarm 6162
Cause:
Effect:
Explanation:
Remedy:
6111
MC5 command STS
STS
command programmed in FB
PLC-STOP
Immediate termination
of
STEP
5 program processing
Cause:
Effect:
Explanation:
6112
MC 5 command STP
STP command
programmed
PLC-STOP
PLC-STOP
after termination of STEP 5 program processing
Cause:
Effect:
Explanation:
6113
Illegal MC5 time/counter
STEP
5 time
or
counter not
available or
not
enabled by MD
PLC-STOP
-
Correct
program
-
alter PLC-MD 6
Cause:
Effect:
Remedy:
6114
Function
macro
Error in an assembler function block
(basic program)
PLC-STOP
See Programming Instructions Function Macros
Cause:
Effect
Remedy:
®