Siemens SINUMERIK 805 Operating Instructions Manual page 194

Table of Contents

Advertisement

8 Monitoring
8.1
General
06.90
8
Monitoring
8.1
General
The control contains constantly active monitoring functions which can recognize faults in the
NC, the interface
control
and the machine early enough for damage
to
the
workpiece,
tool or
machine
to be largely
eliminated.
first of all machining is interrupted and the drives brought
to
a standstill
If a fault does
occur
and the
reason
for the fault is stored and
displayed
as an alarm. At the same time the
PLC is
informed that
an
NC
alarm exists.
Monitoring functions exist for the following
areas:
Read-in
Format
Measuring circuit cables
Encoders and drive
Contour
Spindle speed
Enable signals
Voltage
Temperature
Microprocessors
Serial interfaces
Transfer between NC and PLC
Voltage level of the backup battery
System program memory
User program memory
In addition, 64 PLC
alarms and
64 PLC messages
as well as
1
00
user
cycle alarms are
available
to
the PLC user. The
texts
for these are transferred via RS 232 C interface into the
buffered memory area of the control.
8.2
Alarm numbers and groups/clearing alarms
The SINUMERIK 805 features the following alarm groups:
POWER ON alarms
RS 232 C alarms
RESET
alarms (axis-specific)
RESET alarms
(general)
Acknowledge alarms
NC alarms:
PLC
system
and programming alarms
PLC user alarms
PLC
alarms
PLC user
messages
PLC messages
8-1
®
Siemens AG
1990 All Rights
Reserved
6ZB5 410-OEE02
SINUMERIK
805,
SW2
(BA)

Hide quick links: