8 Monitoring
8.3.3 List of alarms
5000
User cycle alarm
5099
The alarm
has been
called using @ 4c0 in the user cycle
Check the cycle
Explanation:
Remedy:
6000
PLC user error
6063
Explanation:
Remedy:
Initiation bit has been
set
in PLC
user program
Defined by manufacturer
6100
Signal
converter
missing
Cause:
Load and transfer
command for I/O device
which is
not
available, e.g.
L PB, T PB
PLC-STOP
Check I/O address and/or STEP
5
program
Effect:
Remedy:
6101
Illegal MC5
mode
STEP 5 command
cannot
be interpreted
PLC-STOP
Check
and/or reload
PLC
program
Evaluate U-STACK
Cause:
Effect:
Remedy:
6102
Illegal MC5
parameter
Parameter
type
illegal (I, O, T, C, T)
or
parameter
value illegal
PLC-STOP
Check PLC program
Evaluate U-STACK
Cause:
Effect:
Remedy:
®
Siemens AG
1990 All Rights
Reserved
6ZB5 410-0EE02
SINUMERIK
805,
SW2
(BA)
8-30
tllllll.UMilHtUMIJ