8 Monitoring
8.3.3 List of
alarms
06.90
3011
Too many axes progr./axes
programmed twice
-
An axis
has been programmed
twice in the
same block
-
More axes
have been programmed than
exist
in the machine
As for
alarm 3000
Explanation:
Remedy:
3012
Block not in memory
The program has
not
been
terminated
with M02/M03/M17
-
The block number
stated in the jump (@ 100,
11x, 12x, 13x)
has
not
been found in the specified direction
As for alarm 3000
Explanation:
Remedy:
3016
External data input error
Effect:
Explanation:
Data transfer interrupted
For external data input from PLC
to
NC:
-
the code is
incorrect
-
the value is
too
large
-
the dimension identifier is invalid
-
the option is
not
available
-
Check PLC
program
-
check NC-MD, PLC-MD
Remedy:
3018
Distance from
contour too
large
Scan:
Effect:
Explanation:
After NC-START
(Automatic)
-
Machining
stops
The
distance
to
circle
contour
is
too large
after repositioning
(MD 9)
Observe MD
9,
move closer
to contour
Remedy:
3019
Option
not available
The 2nd RS
232 C interface has been
started either using the
softkey or
from the
PLC even
though no option is available for it.
-
Data transfer via the
1st
RS
232 C interface
-
Retrofit option C62 (2nd
RS
232 C interface)
Explanation:
Remedy:
8-27
©
Siemens
AG
1990 All Rights
Reserved
6ZB5
410-0EE02