8 Monitoring
8.3.3 List of alarms
06.90
26
Part prog, block
>
120 characters RS 232 C
The
part
program block that has been read in contains more
than
1
20
characters. Only
the actual stored
characters are
counted
(no
spaces,
no CR,
...)
-
Data transfer interrupted
-
Last block is
not
stored
Divide block into
2
or more blocks
Cause:
Effect:
Remedy:
27
Data input disabled RS 232 C
Cause:
"Cycle lock" interface signal is active:
NC,
PLC
machine data
texts
have been read in without password input.
No data has been stored
-
Reset Q
78.3 via
PLC
status
-
Enter password
(scan
appears when machine data is altered)
Effect:
Remedy:
28
Ring buffer overflow RS
232 C
Effect:
RS232
(V.24) transfer is interrupted
The last blocks are declared as invalid
Data transfer speed
so
high
that more characters are transferred
than
can
be processed by the
NC.
If
the program is transferred again, the faulty program
must be
deleeted beforehand
RTS signal has no
effect on the input device (RTS causes the input
device
to
STOP)
Transmission
speed (baud rate)
too
high
Explanation:
Remedy:
29
Block
>
254 characters RS 232 C
The
read-in
block has more than 254
characters. All read-in characters
(e.g. spaces)
are included in the count.
-
RS 232 C transfer interrupted
-
Last block
is
not
stored
Divide block into
two
or more blocks.
Cause:
Effect:
Remedy:
30
Part program memory full RS 232 C
The maximum
part
program memory is full
-
RS 232 C transfer
interrupted
-
Last block is
not
stored
Delete old programs and
reorganize memory
Cause:
Effect:
Remedy: