06.90
8 Monitoring
8.3.3 List of alarms
2062
Feed missing/not programmed
No F value programmed
-
F value too small
(machine data)
-
Feed
per
rev. G95
programmed greater
than
50 mm/min
No feed per
rev.
programmed
Programm feedrate correctly
Ursache:
Remedy:
2063
Thread lead too high
Effect:
Explanation:
Interlocking
of
NC
START
A thread lead of
more
than 400 mm/rev (16"
/rev)
has been programmed
-
program lower thread leads
-
If necessary, run
program on a machine with SINUMERIK 850
(max.
speed 2000
mm/rev)
Remedy:
2064
Rounding err.
for rotary axis wrongly
prog.
Scan:
Explanation:
On traversing in AUTOMATIC/MDA mode
If you
round
to
either a half or full
degree on
a
rotary
axis, the control
will monitor whether the programmed
positions correlate with the
rounding.
-
Interlocking of NC START
-
Programmed path in block is
no
executed
-
Program
correct rotary
axis position
-
Check MD
560* bits 2 and 3
In the
JOG
and JOG INC
modes, the control automatically rounds to
valid values. In the
AUTOMATIC
or MDA
modes,
the control
only
monitors
the programmed positions without
rounding itself
Effect:
Remedy:
Bemerkung:
2065
Programmed position behind SW limit switch
On
traversing in
AUTOMATIC/MDA
mode
Interlocking of NC
START
-
Programmed
path not executed
The programmed
block end
point lies behind the software limit switch
-
Correct program
-
Check MD
224*, 228*,
232*,
236* in dependence on
PLC interface
signal, "2nd software limit switch valid"
Scan:
Effect:
Explanation:
Remedy:
©
Siemens AG
1990 All Rights Reserved
6ZB5 410-0EE02
SINUMERIK
805,
SW2
(BA)
8-20