06.90
8 Monitoring
8.3.3 List of alarms
7
EPROM
error
Cyclic
Interlocking of NC-START
Setpoint relay drop
(setpoint 0)
Removal
of
NC READY
2
Servo enable
is removed in MD
1
56 after delay
has elapsed
(servo
enable relays drop
out)
An error was detected whilst checking totals
Notify service
Scan:
Effect:
Explanation:
Remedy:
8
Incorrect axis/spindle assignment
Scan:
Effect:
After modification of MD
Interlocking of NC START
Setpoint relay drop (setpoint 0)
Removal of NC READY 2. An illegal assignment had been made in
MD
200* or
MD
400*.
Correct:
(0000)
=>
Axis/spindle
not
available
at
machine (only
permissible with
NC-MD bit
564*.7
=
"0"
(for
axes)
Explanation:
0100
0200
0300
0400
0500
See Section
8 (MD description for
MD
200* and
MD
400*)
Remedy:
12
Part
program
memory wrongly formatted
Scan:
Effect:
On POWER ON
-
Fault in RAM area
-
The
part
program memory size falls below minimum size permitted.
-
Format
part
program memory in initialization mode
Remedy:
13
RAM error
On POWER ON
Error in module RAM area
Format user memory
and format part program
memory in
initialization mode
Change CC
Scan:
Effect:
Remedy:
®
Siemens AG
1990 All Rights
Reserved
6ZB5 410-0EE02
SINUMERIK
805,
SW2
(BA)
8-6
......
ill..:
...

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents