15
. ELECTRICAL EQUIPMENT
SUPER 9
50
Starter Relay
STARTER RELAY INSPECTION
Open the front tool box and remove the bolt.
Remove the front tool box. ( 2-4)
Disconnect the starter relay coupler and then
remove the starter relay.
Connect the starter relay green/yellow
Red
Yellow/Red
terminal to the 12V battery positive (+)
terminal and the relay yellow/red terminal to
the battery negative (-) terminal. Check for
continuity between the starter relay red and
red/white terminals. The relay is normal if
there is continuity.
Red/White
Green/Yellow
STARTER MOTOR REMOVAL
Bolts
Disconnect the starter motor cable.
Remove the two bolts attaching the starter
motor and remove the starter motor.
The installation sequence is the reverse of
removal.
Starter Motor
15-12