1
. GENERAL INFORMATION
Inspection/Adjustment
Check carburetor gasket
for air leaks.
Remove auto bystarter
connecting wire and
check if bypass fuel
line is clogged.
Connect auto bystarter
wire to battery. Wait for
5 minutes, then connect
a hose to fuel enriching
circuit and then blow
the hose with mouth.
Symptom
No air leak
Not clogged
Not Clogged
Clogged
Probable Cause
Carburetor not securely
tightened
Air leaks
Faulty intake manifold gasket
Deformed or broken
carburetor O-ring
Broken cable
Clogged
Dirty auto bystarter
Faulty auto bystarter
Faulty auto bystarter
SUPER 9
50
1-26