Toshiba VF-S15 Instruction Manual page 79

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

 How to search and reprogram parameters
Panel operation
MODE
MODE
MODE
MODE
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
LED display
00
auh
gru
u
acc
or
80
50
50 acc
uf
(ur)
gru
Parameter display
gru
frf
00
Displays the output frequency (operation stopped).
(When standard monitor display selection is set as f710=0
[output frequency])
Displays the first basic parameter "History function (auh)."
Turn the setting dial, and select gru.
Press the center of the setting dial to enter the user parameter setting
change search mode.
Searches for and displays parameters different to the default settings.
Parameters are changed by either pressing the center of the setting
dial or turning it to the right. (Turning the setting dial to the left
searches for parameter in the reverse direction.)
Press the center of the setting dial to display set values.
Turn the setting dial, and change set values.
Press the center of the setting dial to set values. The parameter name
and set value light alternately and are written.
Use the same steps as those above and turn the setting dial to
display parameters to search for or whose settings must be changed,
and check or change the parameter settings.
When gru appears again, the search is ended.
A search can be canceled by pressing the MODE key. Press the key
once while the search is underway to return to the display of
parameter setting mode. Returns to the gru display.
After that press the MODE key and return to the status monitor mode
or the standard monitor mode (display of output frequency).
D-9
E6581611
Operation