 Table of input terminal functions 2
Function
Code
No.
52
IDC
53
IDCN
54
DR
55
DRN
56
FORCE
57
FORCEN
58
FIRE
59
FIREN
60
DWELL
61
DWELLN
62
KEB
63
KEBN
64, 65
70, 71
74
CKWH
75
CKWHN
76
TRACE
77
TRACEN
78
HSLL
79
HSLLN
80
HDRY
81
HDRYN
82
HDOUT
83
HDOUTN
88
UP
89
UPN
90
DWN
91
DWNN
92
CLR
93
CLRN
96
FRR
97
FRRN
98
FR
99
FRN
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
PID integral/differential clear
Inversion of PID integral/differential clear
PID characteristics switching
Inversion of PID characteristics switching
Forced run operation
Inversion of forced run operation
Fire speed operation
Inversion of fire speed operation
Acceleration/deceleration suspend signal
Inversion of acceleration/deceleration
suspend signal
Power failure synchronized signal
Inversion of power failure synchronized signal
Factory specific coefficient
Factory specific coefficient
Integrating wattmeter(kWh) display clear
Inversion of integrating wattmeter display clear
Trace back trigger signal
Inversion of trace back trigger signal
Light-load high-speed operation prohibitive
signal
Inversion of light-load high-speed operation
prohibitive signal
Holding of RY-RC terminal output
Inversion of holding of RY-RC terminal output
Holding of OUT-NO terminal output
Inversion of holding of OUT-NO terminal output
Frequency UP
Inversion of frequency UP
Frequency DOWN
Inversion of frequency DOWN
Clear frequency UP/DOWN
Inversion of clear frequency UP/DOWN
Coast stop command
Inversion of coast stop command
Forward/reverse selection
Inversion of forward/reverse selection
Action
ON: Integral/differential clear, OFF: Clear canceled
Inversion of IDC
ON: Inverted characteristics of  selection
OFF: Characteristics of  selection
Inversion of DR
ON: Forced run operation if specified faults are occurred
( frequency)
OFF: Normal operation
Inversion of FORCE
ON: Fire speed operation ( frequency)
OFF: Normal operation
Inversion of FIRE
ON: Acceleration/deceleration suspend
OFF: Normal operation
Inversion of DWELL
ON: Deceleration stop with synchronizing when power failure
OFF: Normal operation
Inversion of KEB
-
-
ON: Integrating wattmeter(kwh) monitor display clear
OFF: Disabled
Inversion of CKWH
ON: Trigger(start) signal of trace function
OFF: Disabled
Inversion of TRACE
ON: Light-load high-speed operation prohibited
OFF: Light-load high-speed operation permitted
Inversion of HSLL
ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real time according to
conditions.
Inversion of HDRY
ON: Once turned on, OUT-NO are held on.
OFF: The status of OUT-NO changes in real time according
to conditions.
Inversion of HDOUT
ON: Frequency increased
OFF: Frequency increase canceled
Inversion of UP
ON: Frequency decreased
OFF: Frequency decrease canceled
Inversion of DWN
OFF
ON: Clear frequency UP/DOWN
Inversion of CLR
ON: Coast stop (Gate OFF)
OFF: Coast stop canceled
Inversion of FRR
ON: Forward command
OFF: Reverse command
Inversion of FR
K-31
E6581611
Reference
6.24
6.30
6.23
6.19.2
*1
*1
6.36
6.35
6.21
7.2.2
6.10.4
11
3.2.1
6.34.8
7.2.1

Hide quick links: