Toshiba VF-S15 Instruction Manual page 324

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

Communication
Title
No.

0778

0779

0780

0781

0782

0790

0791

0792

0793

0794

0799
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
 Communication parameters
Communication
Title
No.

0800
0801


0802
0803


0804

0805

0806

0808
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Easy setting mode
-
parameter 28
Easy setting mode
-
parameter 29
Easy setting mode
-
parameter 30
Easy setting mode
-
parameter 31
Easy setting mode
-
parameter 32
Panel display
-
selection at power
on
st
nd
1
and 2
hex
characters of
f790
rd
th
3
and 4
hex
characters of
f790
th
th
5
and 6
hex
characters of
f790
th
th
7
and 8
hex
characters of
f790
Factory specific
-
coefficient 7A
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Baud rate
-
Parity
-
Inverter number
-
1/1
Communication
s
0.1/0.1
time-out time
Communication
-
time-out action
Communication
s
0.01/0.01
waiting time
Setting of master
-
and slave for
communication
between inverters
Communication
-
time-out detection
condition
Adjustment range
-
-
-
0-2999
(Set by communication number)
-
-
0: hello
-
1: f791 to f794
2, 3: -
-
0-FFFF
-
0-FFFF
-
0-FFFF
-
0-FFFF
-
-
Adjustment range
-
3: 9600bps
4: 19200bps
5: 38400bps
-
0: No parity
1: Even parity
2: Odd parity
0-247
0.0: Disabled,
0.1-100.0
-
0: Alarm only
1: Trip (Coast stop)
2: Trip (Deceleration stop)
0.00-2.00
-
0: Slave (0 Hz command issued in
case the master inverter fails)
1: Slave (Operation continued in case
the master inverter fails)
2: Slave (Emergency stop tripping in
case the master inverter fails)
3: Master (transmission of frequency
commands)
4: Master (transmission of output
frequency signals)
-
0: Valid at any time
1: Communication selection of
fmod or cmod
2: 1 + during operation
K-25
E6581611
Default
User
Reference
setting
setting
999
4.5
6.37
999
999
701
(F701)
50
(PSEL)
0
6.34.10
2d2d
2d2d
2d2d
2d2d
-
*3
Default
User
Reference
setting
setting
4
6.38.1
1
0
0.0
0
0.00
0
1
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents