Toshiba VF-S15 Instruction Manual page 209

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

3)
6.27.2 Switching of an acceleration/deceleration time 1, 2, 3
f500 : Acceleration time 2
f501 : Deceleration time 2
f503 : Acceleration/deceleration 2 pattern
f504 : Acceleration/deceleration selection (1,2,3) (panel keypad)
f505 : Acceleration/deceleration 1 and 2 switching frequency
f510 : Acceleration time 3
f511 : Deceleration time 3
f512 : Acceleration/deceleration 3 pattern
f513 : Acceleration/deceleration 2 and 3 switching frequency
f519 : Setting of acceleration/deceleration time unit
 Function
Three different times for acceleration and deceleration can be specified individually. Choose from the
following for the method of selection or switching:
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
S-pattern 2 acceleration/deceleration
Select this pattern to obtain slow acceleration in a demagnetizing region with a small motor
acceleration torque. This pattern is suitable for high-speed spindle operation.
Output frequency [Hz]
Maximum frequency

Set frequency
Base frequency
0

Actual acceleration time
1)
Selection by means of parameters
2)
Switching by changing frequencies
3)
Switching by means of terminals
Output frequency [Hz]
Maximum frequency

Set frequency
Base frequency
0
Time [s]
F-97
E6581611

Time [s]
Actual deceleration time
6

Hide quick links: