 List of output terminal function settings
<Explanation of terminology>
 Alarm
 Pre-alarm ...... Alarm output when the inverter may cause a trip during continued operation.
List of detection levels for output terminal selection
Parameter
programmed value
Positive
logic
 
 
 
 
 
 
7
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
...... Alarm output when a setting has been exceeded.
Function
Negative
logic

Frequency lower limit

Frequency upper limit

Low-speed detection signal

Output frequency attainment signal
(acceleration/deceleration completed)

Set frequency attainment signal
 
Fault signal (trip output)
 
Over-current detection pre-alarm
 
Overload detection pre-alarm
 
Overheat detection pre-alarm
 
Overvoltage detection pre-alarm
 
Power circuit undervoltage detection
 
Small current detection
 
Over-torque detection
 
Braking resistor overload pre-alarm
 
Run/Stop
 
Serious failure
 
Light failure
 
Cooling fan ON/OFF
 
In jogging operation
 
Operation panel / terminal block
operation
 
Cumulative operation time alarm
 
Communication option
communication error
 
Forward/reverse run
 
Ready for operation 1
 
Ready for operation 2
 
Brake release
 
Pre-alarm
 
RS485 communication error
 
Designated data output 1
 
Designated data output 2
 
Light load output
Parameter
programmed value
Positive
Negative
logic
logic
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
to 
180
181
182
183
to 


G-10
E6581611
Function
Heavy load output
Lower limit frequency stop
Power failure synchronized operation
Traverse in progress
Traverse deceleration in progress
Parts replacement alarm
Over-torque detection pre-alarm
Frequency setting mode selection 1/2
Panel / remote selection
Forced continuous operation in progress
Specified frequency operation in progress
Signal in accordance of frequency
command
Fault signal (output also at a retry waiting)
PTC input alarm signal
Factory specific coefficient *1
Analog input break detection alarm
F terminal status
R terminal status
Cooling fan replacement alarm
Number of starting alarm
Acceleration operation in progress
Deceleration operation in progress
Constant speed operation in progress
DC braking in progress
Factory specific coefficient *1
Integral input power pulse output signal
Shock monitoring pre-alarm signal
Factory specific coefficient *1
Always OFF
Always ON